IMPLEMENTING LACTATE SCALP TESTING IN PRACTICE OF SURGUT DISTRICT CLINICAL CENTER OF MATERNITY AND CHILDHOOD HEALTH CARE
https://doi.org/10.35266/2304-9448-2023-3-32-41
Abstract
The study aims to compare the outcomes of 160 labor cases and their infants born at gestational age from 37 + 0 to 42 + 0 weeks prior and following the implementation of fetal scalp testing into gynecological practice as an additional method to diagnose fetal hypoxia. The examination included a retrospective study of 80 women in labor and 80 newborns before the scalp test, and a prospective study of another 80 women in labor and 80 newborns after the test. The results of the study demonstrated a reduced number of instrumental deliveries and an improvement in the state and outcomes of newborns with severe asphyxia by the first postnatal year. After intranatal lactate blood sampling in the early neonatal period, newborns with severe asphyxia demonstrated a significantly reduced rate of pathological pattern when their amplitude-integrated electroencephalography was recorded, and their hypoxic-ischemic encephalopathy was lower as well. In 24 months of observation, there were no statistically significant neurological complications in most of the children with severe asphyxia.
About the Authors
L. D. BelotserkovtsevaRussian Federation
Doctor of Sciences (Medicine), Professor
E-mail: info@surgut-kpc.ru
Yu. A. Sherstyuk
Russian Federation
Postgraduate, Anesthesiologist-Resuscitator
E-mail: sjuruk27@gmail.com
References
1. Здравоохранение в России. 2021 : стат. сб. М. : Росстат, 2021. 171 с.
2. Федеральные клинические рекомендации по оказанию медицинской помощи детям с последствиями перинатального поражения центральной нервной системы с синдромом мышечного гипертонуса (утв. Союзом педиатров России 14.02.2015). Доступ из СПС «Гарант».
3. Задворнов А. А., Голомидов А. В., Григорьев Е. В. Неонатальная терапевтическая гипотермия: как она работает? // Неонатология: новости, мнения, обучение. 2016. № 1. С. 49–54.
4. Ayres-de-Campos D., Arulkumaran S., FIGO Intrapartum Fetal Monitoring Expert Consensus Panel. FIGO consensus guidelines on intrapartum fetal monitoring: Introduction. Int J Gynaecol Obstet. 2015;131(1):3–4.
5. Ayres-de-Campos D., Spong C. Y., Chandraharan E. et al. FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography. Int J Gynaecol Obstet. 2015;131(1):13–24.
6. Visser G. H., Ayres-de-Campos D., FIGO Intrapartum Fetal Monitoring Expert Consensus Panel. FIGO consensus guidelines on intrapartum fetal monitoring: Adjunctive technologies. Int J Gynaecol Obstet. 2015;131(1):25–29.
7. Cummins G., Kremer J., Bernassau A. et al. Sensors for Fetal hypoxia and metabolic acidosis: A review. Sensors (Basel). 2018;18(8):2648.
8. Tsikouras P., Koukouli Z., Niesigk B. et al. Predictive value of fetal scalp pH and base excess for fetal acidosis and poor neonatal outcome. J Matern Fetal Neonatal Med. 2018;31(23):3166–3171.
9. Kuehnle E., Herms S., Kohls F. et al. Correlation of fetal scalp blood sampling pH with neonatal outcome umbilical artery pH value. Arch Gynecol Obstet. 2016;294(4):763–770.
10. Demaegd H., Bauters E., Page G. H. Foetal scalp blood sampling and ST-analysis of the foetal ECG for intrapartum foetal monitoring: A restricted systematic review. Facts Views Vis Obgyn. 2020;11(4):337–346.
11. Филиппова Я. Д. Обзор методов диагностики фетальной гипоксии // StudArctic Forum. 2017. Т. 1, № 5. C. 21–32 DOI 10.15393/j102.art.2017.1161.
12. Stål I., Wennerholm U. B., Nordstrom L. et al. Fetal scalp blood sampling during second stage of labor – Analyzing lactate or pH? A secondary analysis of a randomized controlled trial. The Journal of Maternal-Fetal & Neonatal Medicine. 2020;35(6):1100–1207.
13. Вихарева О. Н., Баев О. Р., Кан Н. Е. и др. Определение лактата в крови из предлежащей части плода. Алгоритм действий во время родов. Краткий протокол // Акушерство и гинекология. 2015. № 4. С. 16.
14. Nova StatStrip Xpress Lactate Hospital Meter instructions for use manual. URL: https://www.woodleyequipment.com/docs/manual_statstrip_lactate_meter.pdf (дата обращения: 20.05.2023).
15. Терапевтическая гипотермия у новорожденных детей : клинич. рекомендации. 2019. URL: https://depzdrav.yanao.ru/ (дата обращения: 20.05.2023).
16. ABL800 FLEX. 201206. URL: https://allwales.icst.org.uk/wp-content/uploads/2020/07/ABL800-FLEX-manual.pdf (дата обращения: 20.05.2023).
Review
For citations:
Belotserkovtseva L.D., Sherstyuk Yu.A. IMPLEMENTING LACTATE SCALP TESTING IN PRACTICE OF SURGUT DISTRICT CLINICAL CENTER OF MATERNITY AND CHILDHOOD HEALTH CARE. Vestnik SurGU. Meditsina. 2023;16(3):32-41. (In Russ.) https://doi.org/10.35266/2304-9448-2023-3-32-41